    Pilot Light Out or Furnace Won't Ignite?

    Standing pilots, spark ignition and hot surface igniters

    Home › Winter Heating Help › Pilot light and ignition

    A gas heater cannot make heat without a flame, and the flame has to start somewhere. Depending on its age, your furnace or wall heater lights its burners from a small pilot flame that burns all the time, a pilot that lights only when needed, or a glowing electric igniter. Each fails in its own way, and only one of them is something a homeowner should ever relight. This page helps you work out which kind you have, what you can safely do, and when to leave it alone.

    Smell gas? Do not relight anything. Leave the house, and from outside call 9-1-1, then PG&E at 1-877-660-6789 (PG&E). Do not use light switches, phones or anything that could spark inside. See our gas smell and carbon monoxide steps.

    This guide is part of our Bay Area Winter Heating Help Center. If you are not yet sure the problem is ignition, start with the no-heat checklist.

    Which ignition does your heater have?

    TypeWhere you find itWhat you see or hearCan you relight it?
    Standing pilotWall heaters, floor furnaces, older forced-air furnaces, most tank water heatersA small blue flame burning all the time, plus a gas control knob marked OFF / PILOT / ONYes, following the instructions on the appliance label
    Intermittent pilot (spark)Many furnaces from the 1980s and 1990s, some newer wall heatersRapid ticking when heat is called, then a pilot flame, then the burnersNo. It lights itself; no flame means a part has failed
    Hot surface igniterMost furnaces installed in the last few decadesAn orange glow through the sight glass, then the burners lightNo. There is no pilot to light

    The label on the inside of the burner door, or the rating plate, usually names the ignition system. If you can see a knob that says PILOT, you have a standing pilot.

    Standing pilots: why they go out

    A standing pilot does two jobs. It lights the burners, and it heats a thermocouple (or on some heaters a thermopile) that produces a tiny electric current telling the gas valve "the pilot is lit, it is safe to open". When the pilot goes out, the thermocouple cools and the valve shuts all gas off. That is a safety feature working, not a gas leak.

    Common reasons a pilot goes out:

    • Drafts. A window or door open near a wall heater, wind down a vent on a stormy night, or a floor furnace grate in a drafty hallway.
    • A dirty pilot. Dust and spider webs clog the tiny pilot orifice over a long, warm summer. The flame goes weak and yellow and no longer wraps the thermocouple properly.
    • A worn thermocouple. The pilot lights but goes out as soon as you let go of the knob. It is one of the most common standing-pilot repairs.
    • A gas interruption. After PG&E work, a meter shutoff or a fumigation, every pilot in the house goes out at once.

    Relighting a standing pilot safely

    Only relight if you do not smell gas and the appliance has instructions for it. Every model differs slightly, so the label on your appliance wins over anything written here. The general sequence:

    1. Turn the gas control to OFF and wait. PG&E's guidance is to shut the gas off at the appliance and "always wait five minutes to let gas disperse before trying to relight" (PG&E gas safety). If you smell gas at any point, stop and leave.
    2. Turn the knob to PILOT and press it down (or press the separate reset button). This lets a small amount of gas reach the pilot only.
    3. Light the pilot with the built-in push-button igniter, or a long lighter if the label says to, while keeping the knob pressed.
    4. Keep holding for 30 to 60 seconds (or as the label says) so the thermocouple heats up, then release slowly. The pilot should stay lit.
    5. Turn the knob to ON, replace any covers, and set the thermostat to call for heat. The burners should light cleanly from the pilot.

    Stop after two tries. If the pilot will not light, lights but will not stay lit when you release the knob, burns yellow and lazy, or goes out again within a day, do not keep trying. Repeated relighting will not fix a failed thermocouple, a clogged pilot or a venting problem. Call Cool Aid at 1-800-266-5243, or book PG&E's free relight described below.

    PG&E will relight pilots for free

    Many Bay Area homeowners do not know this. PG&E says it "offers free safety inspections and gas pilot relight appointments" (PG&E help center). The service is open to PG&E's single-family and multifamily residential gas customers, and you book it online at pge.com/appt under Service Requests (PG&E pilot light service). PG&E also runs a winter gas safety campaign that promotes this free appliance inspection and relight program (PG&E 2026 Gas Safety Plan).

    Book PG&E if you are uncomfortable relighting, if every pilot in the house went out after a gas interruption, or if you want an older wall heater or floor furnace looked at before winter. PG&E's visit is a safety check and relight, not a repair. If their technician finds a worn part or tags an appliance as unsafe, that is when you call a heating contractor.

    Intermittent pilots: ticking with no flame

    With an intermittent pilot, the control sends a rapid spark to light a pilot, proves the pilot flame with a sensing rod, then opens the main valve. Typical failures:

    • Ticking, no pilot: a clogged pilot orifice, no gas to the furnace, a cracked spark electrode or a pilot valve that will not open.
    • Pilot lights, burners never follow: the control is not sensing the pilot flame, usually a dirty or worn sensor or a weak pilot.
    • Ticking that never stops, even when the burners are lit: a sensing or control board fault.

    None of these are homeowner repairs. Turn the thermostat down so the system stops trying, and call.

    Hot surface igniters and flame sensors

    Newer furnaces light with a hot surface igniter, a small ceramic element that glows bright orange. It is brittle and wears out with heat cycles. When it fails, you hear the inducer fan start, wait for a glow that never comes, and the furnace retries a few times, then locks out.

    If the burners do light but go out within a few seconds, the usual cause is the flame sensor, a thin metal rod in the flame. Lennox explains that it senses the presence of flame at the burner, and that a dirty flame sensor "will shut off the gas valve and the furnace, which prevents natural gas accumulations that could cause a fire" (Lennox). A sensor with a light coating can often be cleaned; one that is cracked or badly corroded is replaced. When the sensor is only borderline, the furnace may start some days and not others, or run short cycles, which our short cycling guide covers.

    We do not recommend cleaning a flame sensor or touching an igniter yourself. The igniter cracks if touched or bumped, the sensor is inside the burner compartment, and a small wiring or reassembly mistake on a gas appliance matters.

    When ignition trouble is really a safety warning

    Some symptoms point beyond a worn part:

    • A loud boom or whoosh when the burners light (delayed ignition). Gas is building up before it lights. Turn the heater off and call.
    • Flames that roll out of the burner area, scorch marks on the cabinet, or melted wiring near the burners.
    • A yellow, floppy flame or soot around a wall heater or floor furnace grille.
    • A pilot that keeps blowing out on an older wall or floor furnace with no draft you can find, which can mean a venting problem.

    Any of these can go with carbon monoxide. PG&E advises turning off the appliance you suspect if it is safe to do so, getting out, and calling 9-1-1 if anyone has symptoms (PG&E). The California Department of Public Health notes that CO deaths occur most often in the cold winter months and recommends having a qualified technician inspect your furnace every year (CDPH). Our post on the hidden dangers of old heaters explains why older units deserve extra attention, and our wall and floor furnace guide covers those heaters in detail.

    What a technician checks

    For a standing pilot, we check gas pressure, clean or replace the pilot assembly, test the thermocouple's output with a meter and replace it if it is weak, and look at venting and draft. For electronic ignition, we watch the full sequence, measure the igniter's resistance, read the flame signal from the sensor, check the gas valve and read the control board's fault history. We will tell you plainly when an old heater is no longer worth repairing. For typical price ranges, see our Bay Area furnace repair cost guide, and for the bigger picture on no-start problems, why your furnace won't turn on. Every repair carries our 1-year parts and labor warranty.

    Book an ignition or pilot repair

    Frequently asked questions

    Is it dangerous that my pilot light went out?

    On its own, usually not. When a standing pilot goes out, the thermocouple cools and the gas valve closes, so gas stops flowing. It becomes a concern if you smell gas, if the pilot goes out repeatedly, or if it will not stay lit. In those cases, leave it off and have it checked.

    Does PG&E charge to relight a pilot or check my heater?

    PG&E describes its pilot relight and safety inspection appointments as free, for its single-family and multifamily residential gas customers. Book at pge.com/appt. The visit is a relight and safety check; any repair PG&E finds is up to you and your contractor.

    My water heater pilot and my furnace both went out. What does that mean?

    When two appliances lose their flame at the same time, the cause is usually the gas supply rather than either appliance: a meter shutoff, utility work or a fumigation. Do not turn a shut-off meter back on yourself. Contact PG&E, which can restore gas and relight pilots.

    Can I just leave my wall heater pilot off in summer?

    Many owners do, and it saves a little gas. The tradeoff is that spiders and dust get into a cold pilot, so it may be harder to light in fall. Relight it on a mild day before the first cold night, and if it gives you trouble, book PG&E's free relight or a service visit.

    My furnace clicks three times, then nothing. Is the igniter bad?

    Possibly, but clicking can come from several parts: relays on the control board, the inducer pressure switch closing, or a spark igniter. Note whether you see an orange glow or a spark through the sight glass and what the status light blinks. That tells a technician whether to look at the igniter, gas valve, pressure switch or board first.

    How long does a hot surface igniter last?

    It varies with the igniter material, how often the furnace cycles and how clean the system is. A furnace that short cycles lights far more often, which wears an igniter faster. A tune-up includes checking the igniter so a weak one can be replaced before it fails on a cold night.