Commercial Refrigeration Rules in 2026: What Actually Applies

Commercial refrigeration guides for Bay Area businesses

Home › Commercial Refrigeration Guide › Refrigeration Rules 2026

Updated October 14, 2026

Quick answer

In 2026, new walk-in condensing units face a 1,400 GWP refrigerant limit from 27 Jul 2026 and 150 or 300 GWP from 1 Jan 2032; new self-contained reach-ins must be under 150 GWP since 2025, and new self-contained ice machines since 2026. DOE's 2024 and 2025 efficiency rules for walk-ins and reach-ins were cancelled by Congress. Repairs to existing systems are not restricted.

The short version for owners

  • Your existing equipment can still be repaired. EPA states that components used to repair existing systems are not subject to the refrigerant restrictions.
  • New equipment is changing. New self-contained units (reach-ins, prep tables, merchandisers, smaller ice machines) now ship with low-GWP refrigerants, usually R-290.
  • Walk-in condensing units got more time. EPA's 2026 reconsideration rule replaced the original 1 Jan 2026 deadline with an interim 1,400 GWP limit from 27 Jul 2026 and a stricter limit from 1 Jan 2032.
  • The newest DOE efficiency rules are gone. Pages quoting 2027, 2028 or 2029 DOE compliance dates for walk-ins or reach-ins are out of date.
  • Leaks now carry paperwork. Since 1 Jan 2026, HFC systems with 15 lb or more of refrigerant fall under EPA leak-repair rules.

Refrigerant limits for new equipment (EPA Technology Transitions)

EPA restricts high-GWP HFC refrigerants in new equipment by sector. The dates below are from EPA's sector table. For self-contained products the date applies to manufacture and import; for systems it applies to installation.

EquipmentLimitApplies from
Self-contained retail units (reach-ins, prep tables, merchandisers)150 GWP1 Jan 2025
Self-contained ice machines, batch up to 1,000 lb/24 hr or continuous up to 1,200 lb/24 hr150 GWP1 Jan 2026
Larger self-contained ice machinesListed substances prohibited1 Jan 2027
Remote ice machinesListed substances prohibited1 Jan 2027
Retail food remote condensing units (most walk-ins)1,400 GWP, then 150 (200 lb+ charge) or 300 (under 200 lb)27 Jul 2026, then 1 Jan 2032
Cold storage warehouses700 GWP, then 150 or 30027 Jul 2026, then 1 Jan 2032
Supermarket systems1,400 GWP, then 150 or 3001 Jan 2027, then 1 Jan 2032

For reference, R-404A has a GWP of about 3,900, so it cannot be used in a newly installed walk-in condensing unit after 27 Jul 2026. Common replacements such as R-448A and R-449A sit under 1,400.

DOE efficiency rules: what was cancelled

DOE published new efficiency standards for walk-in coolers and freezers on 23 Dec 2024 and for commercial refrigerators and freezers on 21 Jan 2025. Congress disapproved both under the Congressional Review Act; the joint resolutions were signed on 9 May 2025 and DOE withdrew both rules effective 20 May 2025. The withdrawal notices state the rules have no force or effect.

The long-standing walk-in design requirements from the Energy Independence and Security Act of 2007 still apply to walk-ins made since 2009, including automatic door closers, strip curtains or spring-hinged doors, and minimum insulation levels (R-25 for cooler walls, ceilings and doors, R-32 for freezer walls, ceilings and doors, R-28 for freezer floors).

Leak repair rules since 1 Jan 2026

Under EPA's Emissions Reduction and Reclamation rule, owners of appliances with 15 lb or more of HFC refrigerant must calculate a leak rate each time refrigerant is added. For commercial refrigeration the trigger is a 20% annual leak rate; leaks above it must be found and repaired within 30 days, with verification tests. Refrigerants with a GWP of 53 or less are exempt.

In practice: keep the service records your technician leaves, and expect a leak search rather than a top-off when a large system keeps losing charge.

What this means when you repair or replace

  • Repairing an R-404A walk-in: allowed. Refrigerant cost and availability are the real question, which is part of a repair vs replace decision.
  • Replacing a walk-in condensing unit after 27 Jul 2026: the new system needs a refrigerant under 1,400 GWP.
  • Buying a new reach-in or small ice machine: it will almost certainly use R-290, which is flammable; service needs technicians trained for it.
  • California: CARB has its own refrigerant rules for new facilities and large store chains. Ask your contractor which apply to your site before a major remodel.

Changelog

DateChange
27 Jul 2026EPA reconsideration rule takes effect: interim limits for remote condensing units and cold storage
26 May 2026EPA publishes the Technology Transitions reconsideration rule
1 Jan 2026150 GWP limit for new self-contained ice machines; EPA leak-repair rules begin
20 May 2025DOE withdraws the Dec 2024 walk-in and Jan 2025 commercial refrigerator rules
9 May 2025Joint resolutions disapproving both DOE rules signed
1 Jan 2025150 GWP limit for new self-contained retail refrigeration units

When to call a technician

Planning a replacement or a remodel, or told your system needs a refrigerant change? Ask a C-38 contractor to confirm which limits apply to your exact equipment before you buy.

Open 7 days, 8 AM to 5 PM, with emergency service until 9 PM. CA Lic. #776244.

Call 1-800-266-5243Request service online

Frequently asked questions

Is R-404A banned?

Not for repairs. EPA says components used to repair existing systems are not restricted. New walk-in condensing units installed from 27 Jul 2026 must use a refrigerant under 1,400 GWP, which rules out R-404A.

Did DOE's 2028 walk-in efficiency rule take effect?

No. Congress disapproved the December 2024 walk-in rule and DOE withdrew it effective 20 May 2025.

What refrigerant do new reach-ins use?

Since 1 Jan 2025, new self-contained retail units must use refrigerants under 150 GWP. Most manufacturers use R-290 (propane).

Do the leak rules apply to my small reach-in?

The EPA leak-repair rules apply to appliances with 15 lb or more of HFC refrigerant. Most reach-ins hold far less.

Sources