Home › Commercial Refrigeration Guide › Refrigeration Rules 2026
Updated October 14, 2026
Quick answer
In 2026, new walk-in condensing units face a 1,400 GWP refrigerant limit from 27 Jul 2026 and 150 or 300 GWP from 1 Jan 2032; new self-contained reach-ins must be under 150 GWP since 2025, and new self-contained ice machines since 2026. DOE's 2024 and 2025 efficiency rules for walk-ins and reach-ins were cancelled by Congress. Repairs to existing systems are not restricted.
The short version for owners
- Your existing equipment can still be repaired. EPA states that components used to repair existing systems are not subject to the refrigerant restrictions.
- New equipment is changing. New self-contained units (reach-ins, prep tables, merchandisers, smaller ice machines) now ship with low-GWP refrigerants, usually R-290.
- Walk-in condensing units got more time. EPA's 2026 reconsideration rule replaced the original 1 Jan 2026 deadline with an interim 1,400 GWP limit from 27 Jul 2026 and a stricter limit from 1 Jan 2032.
- The newest DOE efficiency rules are gone. Pages quoting 2027, 2028 or 2029 DOE compliance dates for walk-ins or reach-ins are out of date.
- Leaks now carry paperwork. Since 1 Jan 2026, HFC systems with 15 lb or more of refrigerant fall under EPA leak-repair rules.
Refrigerant limits for new equipment (EPA Technology Transitions)
EPA restricts high-GWP HFC refrigerants in new equipment by sector. The dates below are from EPA's sector table. For self-contained products the date applies to manufacture and import; for systems it applies to installation.
| Equipment | Limit | Applies from |
|---|---|---|
| Self-contained retail units (reach-ins, prep tables, merchandisers) | 150 GWP | 1 Jan 2025 |
| Self-contained ice machines, batch up to 1,000 lb/24 hr or continuous up to 1,200 lb/24 hr | 150 GWP | 1 Jan 2026 |
| Larger self-contained ice machines | Listed substances prohibited | 1 Jan 2027 |
| Remote ice machines | Listed substances prohibited | 1 Jan 2027 |
| Retail food remote condensing units (most walk-ins) | 1,400 GWP, then 150 (200 lb+ charge) or 300 (under 200 lb) | 27 Jul 2026, then 1 Jan 2032 |
| Cold storage warehouses | 700 GWP, then 150 or 300 | 27 Jul 2026, then 1 Jan 2032 |
| Supermarket systems | 1,400 GWP, then 150 or 300 | 1 Jan 2027, then 1 Jan 2032 |
For reference, R-404A has a GWP of about 3,900, so it cannot be used in a newly installed walk-in condensing unit after 27 Jul 2026. Common replacements such as R-448A and R-449A sit under 1,400.
DOE efficiency rules: what was cancelled
DOE published new efficiency standards for walk-in coolers and freezers on 23 Dec 2024 and for commercial refrigerators and freezers on 21 Jan 2025. Congress disapproved both under the Congressional Review Act; the joint resolutions were signed on 9 May 2025 and DOE withdrew both rules effective 20 May 2025. The withdrawal notices state the rules have no force or effect.
The long-standing walk-in design requirements from the Energy Independence and Security Act of 2007 still apply to walk-ins made since 2009, including automatic door closers, strip curtains or spring-hinged doors, and minimum insulation levels (R-25 for cooler walls, ceilings and doors, R-32 for freezer walls, ceilings and doors, R-28 for freezer floors).
Leak repair rules since 1 Jan 2026
Under EPA's Emissions Reduction and Reclamation rule, owners of appliances with 15 lb or more of HFC refrigerant must calculate a leak rate each time refrigerant is added. For commercial refrigeration the trigger is a 20% annual leak rate; leaks above it must be found and repaired within 30 days, with verification tests. Refrigerants with a GWP of 53 or less are exempt.
In practice: keep the service records your technician leaves, and expect a leak search rather than a top-off when a large system keeps losing charge.
What this means when you repair or replace
- Repairing an R-404A walk-in: allowed. Refrigerant cost and availability are the real question, which is part of a repair vs replace decision.
- Replacing a walk-in condensing unit after 27 Jul 2026: the new system needs a refrigerant under 1,400 GWP.
- Buying a new reach-in or small ice machine: it will almost certainly use R-290, which is flammable; service needs technicians trained for it.
- California: CARB has its own refrigerant rules for new facilities and large store chains. Ask your contractor which apply to your site before a major remodel.
Changelog
| Date | Change |
|---|---|
| 27 Jul 2026 | EPA reconsideration rule takes effect: interim limits for remote condensing units and cold storage |
| 26 May 2026 | EPA publishes the Technology Transitions reconsideration rule |
| 1 Jan 2026 | 150 GWP limit for new self-contained ice machines; EPA leak-repair rules begin |
| 20 May 2025 | DOE withdraws the Dec 2024 walk-in and Jan 2025 commercial refrigerator rules |
| 9 May 2025 | Joint resolutions disapproving both DOE rules signed |
| 1 Jan 2025 | 150 GWP limit for new self-contained retail refrigeration units |
When to call a technician
Planning a replacement or a remodel, or told your system needs a refrigerant change? Ask a C-38 contractor to confirm which limits apply to your exact equipment before you buy.
Open 7 days, 8 AM to 5 PM, with emergency service until 9 PM. CA Lic. #776244.
Frequently asked questions
Is R-404A banned?
Not for repairs. EPA says components used to repair existing systems are not restricted. New walk-in condensing units installed from 27 Jul 2026 must use a refrigerant under 1,400 GWP, which rules out R-404A.
Did DOE's 2028 walk-in efficiency rule take effect?
No. Congress disapproved the December 2024 walk-in rule and DOE withdrew it effective 20 May 2025.
What refrigerant do new reach-ins use?
Since 1 Jan 2025, new self-contained retail units must use refrigerants under 150 GWP. Most manufacturers use R-290 (propane).
Do the leak rules apply to my small reach-in?
The EPA leak-repair rules apply to appliances with 15 lb or more of HFC refrigerant. Most reach-ins hold far less.
Related guides
Sources
- EPA: Technology Transitions HFC restrictions by sector
- Federal Register: Technology Transitions reconsideration rule (26 May 2026)
- Federal Register: DOE withdraws walk-in cooler and freezer standards (20 May 2025)
- Federal Register: DOE withdraws commercial refrigerator standards (20 May 2025)
- EPA fact sheet: AIM Act leak repair requirements (Jan 2026)
- 40 CFR 84.106: leak repair
- 10 CFR 431.306: walk-in cooler and freezer requirements